3 analog input, Figure 114: the gpi/o defined as digital output, Figure 115: ethernet settings example – Kramer Electronics WP-501 User Manual

Page 74

Advertising
background image

K-Config

Assigning the Peripheral Devices to Master and Auxiliary Device Ports

69

Figure 114: The GPI/O Defined as Digital Output

7.2.3

Analog Input

The analog input accepts an analog signal from an auxiliary device:

The Pullup and Threshold features are disabled.

The trigger is activated once when the voltage is within a certain range of voltages.

7.3

Assigning a Peripheral Device Driver to an Ethernet Port

The Ethernet ports let you send serial commands via the Ethernet port to up to 10 IP addresses located on the same

subnet.

To define an Ethernet port, do the following:

1.

Set the Ethernet port Driver and Description.

2.

Click the Properties field to define the Ethernet Settings:

Figure 115: Ethernet Settings Example