Pump Ends
p/n: 029-0020-61-0

In tro d u ctio n

60FBG Series, with Gearbox

Standard centrifugal pump and gearbox assembly with universal
mounting bracket designed to bolt directly to either SAE #2 or #3
engine flywheel housing and available for gasoline or diesel engines.

Pump delivers discharge pressures up to 250 PSI (17 BAR) and flow
rates up to approximately 1,500 GPM (5,678 LPM / 95 LPS), NFPA
1901 performance rated.

Suction — 6” (152 mm) female NPT flange, optional

Discharge — 4” (102 mm) flange / 4” NPT check valve, optional

60FJ Series, Bell Housing Mount

Standard centrifugal pump end with universal mounting bracket
designed to bolt directly to either SAE #10 or #11 engine flywheel
housing and splined shaft, available for gasoline or diesel engines.

Pump delivers discharge pressures up to 250 PSI (17 BAR) and flow
rates up to approximately 1,200 GPM (4,543 LPM / 76 LPS), NFPA
1901 performance rated.

Suction — 6” (152 mm) female NPT flange, optional

Discharge — 4” (102 mm) flange / 4” NPT check valve, optional

80FC Series, Bell Housing Mount

Standard centrifugal pump end with universal mounting bracket
designed to bolt directly to either SAE #11 or #4 engine flywheel hous-
ing and available for gasoline or diesel engines.

Pump delivers discharge pressures up to 160 PSI (11 BAR) and flow
rates up to approximately 3,000 GPM (11,356 LPM / 189 LPS), NFPA
1901 performance rated.

Suction — 8” (203 mm) female NPT flange, optional

Discharge — 6” (152 mm) flange, optional

80FC (-G or -U) Series, with gearbox (-G) or pedestal (-U)

Standard centrifugal pump and gearbox (or pedestal) assembly with
universal mounting bracket designed to bolt directly to either SAE #?
or #? engine flywheel housing and available for gasoline or diesel
engines.

Pump delivers discharge pressures up to 250 PSI (17 BAR) and flow
rates up to approximately 3,000 GPM (11,356 LPM / 189 LPS), NFPA
1901 performance rated.

Suction — 8” (203 mm) female NPT flange, optional

Discharge — 4” (152 mm) flange / 6” NPT check valve, optional