Figure 6a-3: typical suction flange option, Installation notes - suction flange, Volute (pump body) – Hale 80FC User Manual

Page 91: Installation notes – suction flange

Advertising
background image

91

Pump Ends
p/n: 029-0020-61-0

Co rr ec tive M ain te n an ce

1.

Review heading 6a.1 “General Preparation” on page 85.

2.

Disconnect the suction, dis-
charge and cooling lines, and any
electrical wiring, if applicable.

3.

Match mark the volute and flange
to ensure proper alignment at
reassembly.

4.

Remove the eight (8) 3/4”-10
screws and washers holding the
flange option to the volute. (See
Figure 6a-3: “Typical Suction
Flange Option.”)

Support the weight of the flange.
It can be heavy and bulky.

Installation Notes – Suction Flange

(See Figure 6a-3: “Typical Suction
Flange Option.”)

To install the flange follow the preced-
ing steps in the reverse order paying
attention to the following:

Review heading 6a.1 “General Preparation” on page 85.

Install a NEW gasket. Apply Loctite to all screws and tighten in a criss-cross
pattern to ensure an EVEN seal.

Refer to Table 6-1: “Typical Torque Values Chart” on page 79 for recom-
mended fastener size, material and torque value.

Set up apparatus for pumping and test pump. Check for leaks at the piping
and seal areas before returning apparatus to operation.

Volute (Pump Body)

On certain pumps, the volute is sealed to the pump housing using an O-ring
and gasket. The O-ring must be inspected for splits, cracks, flat spots, etc. All
other pumps are sealed by a gasket only. (See Figure 6a-4: “Typical Pump Dis-
assembly Overview” on page 92.)

1.

Review heading 6a.1 “General Preparation” on page 85.

Figure 6a-3: Typical Suction Flange Option

Advertising
This manual is related to the following products: