Figure 4-1: typical drain, fill and level plugs, Pedestal option, To check / add oil – Hale 80FC User Manual

Page 57

Advertising
background image

57

Pump Ends
p/n: 029-0020-61-0

Pr ev en tive M ain te n an ce

Figure 4-1: Typical Drain, Fill and Level Plugs

3.

If the oil appears white or “milky,” a water leak is indicated. Remove the
drain plug and drain the oil into a suitable container. Examine the oil for
metal flakes or other contamination.

Note: If water leak / contamination is suspected, see heading “Troubleshooting” on
page 49.

4.

Either of these conditions indicates maintenance is required on the unit.
See Section 6 “Repair” on page 77.

Pedestal Option

For pedestal reservoir capacity review the appropriate pump installation and
parts identification drawing —

see heading “Drawing Package” on page 151.

To Check / Add Oil

1.

Remove the oil FILL plug, and check the level of the oil in the reservoir.
(See Figure 4-2: “Typical Pedestal Oil Servicing” on page 58.)