Installation notes - impeller, Installation notes – impeller, Caution – Hale 80FC User Manual

Page 96

Advertising
background image

Corrective Maintenance

96

Pump Ends

p/n: 029-0020-61-0

Figure 6a-6: Clearance Ring and Impeller ID / OD Measurement

The impeller hub diameter can be cut (turned down) and “undersized” clear-
ance rings can be ordered to compensate for a new impeller diameter. Contact
Customer Service at Hale Products at 610-825-6300.

CAUTION !

WHEN TURNING IMPELLERS TO FIT UNDERSIZED RINGS, CAUTION MUST BE
EXERCISED TO ENSURE THAT THE SEAL RING SURFACE RUNS TRUE WITH
THE BORE TO WITHIN 0.002” (0.051MM).

Installation Notes – Impeller

Follow the preceding steps in the reverse order, while paying attention to the fol-
lowing:

Review heading 6a.1 “General Preparation” on page 85.

Review heading 6a.1 “General Preparation” on page 85.

Align the impeller to the keyway, then slide onto the pump shaft.

For 30 FS series pumps - apply Loctite to the threads, then instal the 3/4”-
16 nut and washer and torque to approximately 104 ft.-lbs. (141 N-m)

For all other pump models

Apply Loctite to the threads, then install the impeller nut and torque to 210
ft.-lbs. (285 N-m) minimum.

Continue tightening the impeller nut until the cotter pin can be installed to
lock the nut in place.

Install cotter pin and bend over the ends.

Advertising