SECTION 4 - HYDRAULICS

4-6

– JLG Lift –

3121166

4.7

PUMP/MOTOR

Theory of Operation

The Power Module (see Figure 3-32., Sevcon Power
Module Location on page 3-38
) is essentially a "low-
side" switch for the pump motor. The positive terminal
of the pump is tied to Battery Positive after the Line
Contactor. The negative terminal of the pump connects
to the P Terminal of the Power Module, which switches
current through MOSFET transistors to the Battery Neg-
ative.

For variable speed pump operation, the MOSFET transis-
tors switch On and Off at high frequencies (16kHz). The
Duty Cycle is varied to control the voltage applied to the
pump motor. When the MOSFET's spend 50% of the
period On and 50% Off, approximately ½ of the avail-
able Battery Voltage will be applied to the pump motor.
Similarly, the MOSFET are On continuously (100% Duty
Cycle) to apply all available Battery Voltage to the pump
motor (as in Lift Up at full speed).

When the Control System is energized, the voltage at
the P Terminal will be approximately +24V (referenced
to -B) when the pump is static. The P Terminal will be
approximately at +1V (referenced to -B) when the pump
is running at full speed (Lift Up from Ground Mode).

-B

P

+B

Series DC

Pump Motor

24V

Line Contactor

Power Module