SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-12

– JLG Lift –

3121166

335

LIFT DN SHORT TO BAT-
TERY

The ground board detected
voltage while the lift down sole-
noid was commanded off.

• Check ANALYZER -> MACHINE SETUP -> ELEV PROX is

set to NOT INSTALLED

• Check for continuity through this circuit. The lift down

solenoid resistance should measure about 20 Ohms.
The lift down solenoid is powered (PWM) by ground
board J1-26, and its ground is to ground board J1-27.

• Inspect the wiring for physical damage.
• Replace ground board.

336

LIFT DN OPEN CIRCUIT

The ground board did not
detect current flow to the lift
down solenoid during normal
operation.

• Check for continuity through this circuit. The lift down

solenoid resistance should measure about 20 Ohms.
The lift down solenoid is powered (PWM) by ground
board J1-26, and its ground is to ground board J1-27.

• Inspect the wiring for physical damage.
• Replace ground board.

337

STEER LEFT SHORT TO
BATTERY

The ground board detected
voltage while the steer left sole-
noid was commanded off at
power up.

• Check for continuity through this circuit. Steer left

solenoid resistance should measure about 30 Ohms.
The steer left solenoid is powered with 24V from
ground board J1-21, and its ground is to ground
board J1-30, 37.

• Inspect the wiring for physical damage.
• Replace ground board.

338

STEER LEFT OPEN CIR-
CUIT

The ground board did not
detect current flow to the steer
left solenoid during normal
operation.

• Check for continuity through this circuit. Steer left

solenoid resistance should measure about 30 Ohms.
The steer left solenoid is powered with 24V from
ground board J1-21, and its ground is to ground
board J1-30, 37.

• Inspect the wiring for physical damage.
• Replace ground board.

339

STEER RIGHT SHORT TO
BATTERY

The ground board detected
voltage while the steer right
solenoid was commanded off.

• Check for continuity through this circuit. Steer right

solenoid resistance should measure about 30 Ohms.
The steer right solenoid is powered with 24V from
ground board J1-22, and its ground is to ground
board J1-30, 37.

• Inspect the wiring for physical damage.
• Replace ground board.

3310 STEER RIGHT OPEN CIR-

CUIT

The ground board did not
detect current flow to the steer
right solenoid during normal
operation.

• Check for continuity through this circuit. Steer right

solenoid resistance should measure about 30 Ohms.
The steer right solenoid is powered with 24V from
ground board J1-22, and its ground is to ground
board J1-30, 37.

• Inspect the wiring for physical damage.
• Replace ground board.

3311 GROUND ALARM

SHORT TO BATTERY

The ground board detected
voltage while the ground alarm
was commanded off.

• Check for continuity through this circuit. The ground

alarm solenoid is powered with 24V from ground
board J1-19, its PWM signal is from ground board J1-
28, and its ground is to ground board J1-30, 37. There
should be about 1500 Ohms between ground alarm
connector pin 1 and pin 3.

• Inspect the wiring for physical damage.
• Replace ground board.

3-3 Ground Output Driver