9 hardware – JLG 3246ES Service Manual User Manual

Page 175

Advertising
background image

SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121166

– JLG Lift –

6-23

9970 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module detected a mismatch in the

redundant RAM information stored in the interface
PCB.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - ON

9971 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s MC/EB valve activation pin is

shorted. This is an internal fault.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99143 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s power and interface PCB digital

inputs do not agree.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99144 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s MC feedback from the interface

PCB disagrees with the feedback from the power PCB.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99145 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s enable for the power PCB

requested a drive motor or valve activation when not
expected.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99146 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s lift down feedback voltage to

the interface and power PCB’s disagrees.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99147 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s VMN feedback voltage to the

interface and power PCB’s disagrees.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99148 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s setpoint request from the inter-

face PCB does not match the input state.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

99149 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module encountered an unexpected

software issue.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9-9 Hardware

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

Advertising
This manual is related to the following products: