2 tilt sensor calibration, Ground module software version 1.5, Ground module software version 1.4 – JLG 3246ES Service Manual User Manual

Page 125: Tilt sensor calibration -5

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

3121166

– JLG Lift –

5-5

CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE PER-
FORMANCE OF YOUR MACHINE.

NOTICE

IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-WASH-
ING BE UTILIZED TO WASH AREAS CONTAINING ELECTRICAL/
ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. RECOM-
MENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A MINI-
MUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS ARE
SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR BRIEF
TIME PERIODS TO AVOID HEAVY SATURATION.

The flash code is indicated on the face of the platform
control box as shown:

Diagnostic Trouble Codes are indicated on the MDI for
those machines that are equipped with an MDI. (refer to
Section 3.2).

NOTE: Flash codes and DTC’s are also displayed on the

handheld analyzer. For descriptions see, Table 5-2,
Flash Code Listing.

5.2

TILT SENSOR CALIBRATION

Be sure that the machine is parked and stowed on level
ground.

NOTE: Tilt Sensor Calibration can not be performed if the

main contactor switch is open due to an alarm.

Ground Module Software Version 1.5

1.

Enter Access Level 1 and go to the CALIBRATION/
TILT SENSOR/LEVEL VEHICLE screen.

2.

Choose the right arrow key to view the raw, uncali-
brated tilt sensor values. If either raw angle reads

±5.0 or more, the machine is too unlevel and the
software will prohibit calibration. Therefore,
attempt to dissect the three areas of error to find
the primary contributor:

a. Machine mounting and/or grade:

Try to measure the top of the Ground Control
box for levelness. If unable to get a good read-
ing, unbolt the Ground Control box and check
the box’s mounting surface for levelness.

b. Tilt sensor mounting on machine or wedged

crooked in control box:
If the machine mounting/grade appears
acceptable, remove and open the Ground Con-
trol box carefully. Observe whether the tilt sen-
sor is properly seated in its grooves.

c. Tilt sensor has developed an offset shift:

Remove the tilt sensor from the Ground Con-
trol box but keep both the tilt sensor and
Ground Control box electrically connected.
Level one axis of the tilt sensor and observe
the raw reading (should be within ± 2.0). Do
the same for the other axis. If either axis is
greater than ±2.0, replace the tilt sensor.

Ground Module Software Version 1.4

1.

Enter Access Level 1 and go to the CALIBRATION/
TILT SENSOR/LEVEL VEHICLE screen.

2.

Choose the right arrow key to view the raw, uncali-
brated tilt sensor values. If either raw angle reads

±5.0 or more, the machine is too unlevel and the
software will prohibit calibration. Therefore,
attempt to dissect the three areas of error to find
the primary contributor:

a. Machine mounting and/or grade:

Try to measure the top of the Ground Control
box for levelness. If unable to get a good read-
ing, unbolt the Ground Control box and check
the box’s mounting surface for levelness.

b. Tilt sensor mounting on machine or wedged

crooked in control box:
If the machine mounting/grade appears
acceptable, remove and open the Ground Con-

SYSTEM FAULT