JLG 3246ES Service Manual User Manual

Page 123

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

3121166

– JLG Lift –

5-3

Changing the Access Level of the Hand Held
Analyzer:

When the analyzer is first connected, you will be in
access level 2 which enables you to only view most con-
figuration settings which cannot be changed until you
enter a password to advance to a lower level. This
ensures that a setting cannot be accidentally altered. To
change the access level, the correct password must be
entered. To enter the password, scroll to the ACCESS
LEVEL
menu. For example:

MENU:

ACCESS LEVEL 2

Press ENTER to select the ACCESS LEVEL menu.

Using the UP or DOWN arrow keys, enter the first digit
of the password, 3.

Then using the RIGHT arrow key, position the cursor to
the right one space to enter the second digit of the
password.

Use the UP or DOWN arrow key to enter the second
digit of the password which is 3.

Repeat this process until you have entered all five digits
of the password which is 33271.

Once the correct password is displayed, press ENTER.
The access level should display the following, if the pass-
word was entered correctly:

MENU:

ACCESS LEVEL 1

Repeat the above steps if the correct access level is not
displayed or you can not adjust the personality settings:

MENU:
ACCESS LEVEL 2

MENU:
ACCESS LEVEL 1