SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121166

– JLG Lift –

6-11

314

AUXILIARY RELAY - OPEN
CIRCUIT

The auxiliary relay did not close
when energized.

• Check the auxiliary relay coil and associated wiring to

J1-13 and J1-32.

• No voltage on J1-28.
• HEALTH (Status LED) - ON

3-2 Line Contactor Short Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

321

LINE CONTACTOR
MISWIRED ON OR
WELDED

Battery voltage was present at
the power module B+ terminal
at power up. Drive, steer and lift
up prevented.

• Check wiring of contactor.
• Check resistance between the studs of the contactor

while disconnected from the machine.

• Check contactor main contact wiring to battery (+)

terminal and power module terminal B+.

• Check continuity between contactor connector pin 1

and ground board socket J1-19.

• Check continuity between contactor connector pin 2

and power module 12 position connector terminal 8.

• Measure voltage between power model B+ and B- ter-

minals. If 24V is present, replace line contactor.

• Replace power module.

322

CONTACTOR DRIVER
PERMANENTLY ON

The power modules line contac-
tor drive circuitry failed to de-
energize when requested. Drive,
steer and lift up prevented.

• Check continuity between contactor connector pin 1

and ground board socket J1-19.

• Check continuity between contactor connector pin 2

and power module 12 position connector terminal 8.

• Replace power module.

3-3 Ground Output Driver

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

331

BRAKE SHORT TO BAT-
TERY

The ground board detected
voltage while the brake sole-
noid was commanded off.

• Ensure ANALYZER -> MACHINE SETUP -> ELEV PROX is

set to NOT INSTALLED.

332

BRAKE OPEN CIRCUIT

The ground board did not
detect current flow to the brake
solenoid during normal opera-
tion.

• Ensure ANALYZER -> MACHINE SETUP -> ELEV PROX is

set to NOT INSTALLED.

333

LIFT UP SHORT TO BAT-
TERY

The ground board detected
voltage while the lift up sole-
noid was commanded off at
power up.

• Check for continuity through this circuit. The lift up

solenoid resistance should measure about 30 Ohms.
The lift up solenoid is powered with 24V from ground
board J1-25, and its ground is to ground board J1-30,
37.

• Inspect the wiring for physical damage.
• Replace ground board.

334

LIFT UP OPEN CIRCUIT

The ground board did not
detect current flow to the lift up
solenoid during power up.

• Check for continuity through this circuit. The lift up

solenoid resistance should measure about 30 Ohms.
The lift up solenoid is powered with 24V from ground
board J1-25, and its ground is to ground board J1-30,
37.

• Inspect the wiring for physical damage.
• Replace ground board.

3-1 Line Contactor Open Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK