7.4

WORKING WITH DEUTSCH CONNECTORS

DT/DTP Series Assembly

Figure 7-12. DT/DTP Contact Installation

1. Grasp crimped contact about 25mm behind the contact barrel.

2. Hold connector with rear grommet facing you.

3. Push contact straight into connector grommet until a click is felt. A slight tug will confirm that it is properly locked

in place.

4. Once all contacts are in place, insert wedgelock with arrow pointing toward exterior locking mechanism. The

wedgelock will snap into place. Rectangular wedges are not oriented. Thy may go in either way.

NOTE: The receptacle is shown - use the same procedure for plug.

DT/DTP Series Disassembly

Figure 7-13. DT/DTP Contact Removal

5. Remove wedgelock using needlenose pliers or a hook shaped wire to pull wedge straight out.

6. To remove the contacts, gently pull wire backwards, while at the same time releasing the locking finger by moving

it away from the contact with a screwdriver.

7. Hold the rear seal in place, as removing the contact may displace the seal.

HD30/HDP20 Series Assembly

Figure 7-14. HD/HDP Contact Installation

8. Grasp contact about 25mm behind the contact crimp barrel.

9. Hold connector with rear grommet facing you.

10. Push contact straight into connector grommet until a positive stop is felt. A slight tug will confirm that it is prop-

erly locked in place.