SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121166

– JLG Lift –

6-15

444

LSS BATTERY VOLTAGE
TOO LOW

The load sensing system mod-
ule momentarily measured bat-
tery voltage < 9V.

• Recharge batteries or check for damaged batteries.
• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

446

LOGIC SUPPLY VOLTAGE
OUT OF RANGE

The system module logic supply
voltage was measured to be out
of normal operating range by
the interface PCB (<11V).

• This may be caused by a loose battery terminal,

severely discharged batteries, damaged battery, or an
improper wire harness connection.

• Drive, Steer, and Lift Prevented
• ZAPI - HEALTH (Status LED) - ON

4421 LOGIC SUPPLY VOLTAGE

OUT OF RANGE

The system module logic supply
voltage was measured by the
power PCB to be more than 34V
for 10uS.

• This may be caused by a loose battery terminal,

severely discharged batteries, damaged battery, or an
improper wire harness connection.

• Drive, Steer, and Lift Prevented
• ZAPI - HEALTH (Status LED) - ON

4422 LOGIC SUPPLY VOLTAGE

OUT OF RANGE

The system module logic supply
voltage was measured by the
power PCB to be less than 11V
for 10uS.

• This may be caused by a loose battery terminal,

severely discharged batteries, damaged battery, or an
improper wire harness connection.

• Drive, Steer, and Lift Prevented
• ZAPI - HEALTH (Status LED) - ON

6-6 Communication

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

661

CANBUS FAILURE -
POWER MODULE

The control system failed to
receive messages from the
power module.

• Check for 24V between power module 12 position

connector terminal 1 and the power module B- termi-
nal. If this is the problem, the line contactor may be
cycling on and off, making a clicking noise when the
machine is powered.

• Disconnect ground board J1 and power module con-

nector. Ground board socket J1-31 to power module
connector socket 10 should have continuity. Ground
board socket J1-32 to power module connector
socket 11 should have continuity.

• Turn on machine in platform mode. If DTC 662 is pres-

ent, troubleshoot that DTC before continuing.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK