9 power module - zapi, Power module - zapi -40, Zapi power module location -40 – JLG 3246ES Service Manual User Manual

Page 76: Zapi power module specs -40

Advertising
background image

SECTION 3 - CHASSIS & SCISSOR ARMS

3-40

– JLG Lift –

3121166

3.9

POWER MODULE - ZAPI

ES Scissors built starting in mid year 2010 replaced the
Sevcon Power Module with the ZAPI Power Module (P/
N-1001092456).

The power module is located behind a protective cover
at the front of the machine as shown in Figure 3-33.,
ZAPI Power Module Location. U
se the following instruc-
tions when replacing the power module.

1.

Turn machine power off and disconnect the bat-
teries.

2.

Locate and remove the power module protective
cover from the machine.

3.

Note the wire terminal locations when removing
the old power module.

4.

Disconnect all wire connectors and cables from
the old power module and remove it from the
machine.

5.

When installing the new power module, be sure
that the terminals are oriented as shown in Figure
3-33.

6.

After installing the new power module, begin con-
necting the wire connectors/cables to the module.

7.

Torque all terminal bolts to torque specifications
shown on the front of the module.

8.

After all connections to the power module are
made, the batteries can be reconnected.

9.

Reinstall the power module cover, then check for
normal machine operation.

Figure 3-33. ZAPI Power Module Location

MACHINE FRONT

ZAPI POWER MODULE

Table 3-2. ZAPI Power Module Specs

Operating Voltage ( B+)

14.5 to 40 VDC

Maximum Current Limits:
Armature
Field
Pump

300 A

40 A

180 A

Standby Current

150 mA

Temperature Range:
Operating
Storage
Thermal Limit

-40°C to 75°C

-40°C to 125°C

75°C to 90°C

Switching Frequency

16 kHz

Advertising
This manual is related to the following products: