Battery algorithms -47 – JLG 3246ES Service Manual User Manual

Page 83

Advertising
background image

SECTION 3 - CHASSIS & SCISSOR ARMS

3121166

– JLG Lift –

3-47

Checking/Changing the Battery Charge Algorithm

The charger is pre-loaded with programming algo-
rithms for the specific batteries detailed in Table 3-4,
Battery Algorithms
. Contact JLG if your specific battery
model is not listed.
Each time AC power is applied with the battery pack not
connected, the charger enters an algorithm select/dis-
play mode for approximately 11 seconds. During this
time, the current Algorithm # is indicated on the Yellow
Charging LED. A single digit Algorithm # is indicated by
the number of blinks separated by a pause. A two digit
Algorithm # is indicated by the number of blinks for the
first digit followed by a short pause, then the number of
blinks for the second digit followed by a longer pause.

To check/change the charging algorithm:

1.

Disconnect the charger positive connector from
the battery pack. Apply AC power and after the
LED test, the Algorithm # will display for 11 sec-
onds.

2.

To change the algorithm, touch the connector to
the battery’s positive terminal for 3 seconds during
the 11 second display period and then remove.
The Algorithm # will advance after 3 seconds.
Repeat this procedure until the desired Algorithm
# is displayed. A 30 second time-out is extended
for every increment. Incrementing beyond the last
Algorithm will recycle back to the first Algorithm.
When the desired Algorithm is displayed, touch
the charger connector to the battery positive ter-
minal until the output relay makes a clicking noise
(approx. 10 seconds). The algorithm is now in the
permanent memory.

3.

Remove the AC power from the charger and
reconnect the charger’s positive connector to the
battery. It is recommended to check a newly
changed algorithm by repeating the above steps 1
and 3.

Table 3-4. Battery Algorithms

Algorithm #

Battery Type

43

Harris Battery Discover EVGC6A-A (AGM)

35

JLG P/N 0400242

23

Douglas Flooded (JLG default)

GES Battery A1055

Trojan T105

East Penn GC-110-WNL

Trojan T105 PLUS

Champion CHGC2 GC2

US BATT EV-145-WNL

US BATT 2200 XC

8

Concorde 10xAh AGM

7

J305 DV/DT CP

6

DEKA 8G31 Gel

5

Trojan 30/31XHS

4

US Battery USB2200

3

T105 DV/DT CP

2

Trojan T105 tapped

1

Trojan T105

Advertising
This manual is related to the following products: