7 electric motor – JLG 3246ES Service Manual User Manual

Page 170

Advertising
background image

SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-18

– JLG Lift –

3121166

773

CAPACITOR BANK
FAULT - CHECK POWER
CIRCUITS

Drive, Steer, and Lift Prevented

• There is an internal or external fault that prevents the

System Module’s capacitor bank from charging.

• The System Module detected that the VMN of the

pump and traction has not increased more than 1.3V
in 1000mS. Alternately, the VMN of the pump or trac-
tion is less than 20% of battery voltage.

• If this message persists after disconnecting the drive

and pump wiring, there is an internal fault.

• ZAPI - HEALTH (Status LED) - ON

774

SHORT CIRCUIT FIELD
WIRING

Drive, Steer, and Lift Prevented

• The field wiring passed System Module power-up

diagnostics. However, an external short circuit was
detected when current was applied to F1 / F2. This sit-
uation is caused by improper field wiring or a dam-
aged motor.

• ZAPI - HEALTH (Status LED) - ON

NOTE: Tilt Sensor Calibration is not available when this

condition is present.

775

OPEN CIRCUIT FIELD
WIRING

Drive, Steer, and Lift Prevented

• The System Module applied field current, but could

regulate the desired current. The situation is caused
by improper field wiring or a damaged motor.

• ZAPI - HEALTH (Status LED) - ON

776

STALLED PUMP MOTOR
OR POWER WIRING
ERROR

Drive, Steer, and Lift Prevented

• The System Module measured improper pump cur-

rent feedback (>4.5V or <0.5V) for 240mS. This is
caused by a stalled pump motor, a power wiring
issue, or a System Module malfunction.

• ZAPI - HEALTH (Status LED) - ON

777

OPEN CIRCUIT PUMP
MOTOR WIRING

Drive, Steer, and Lift Prevented

• The System Module measured pump current less

than 8A while the motor voltage was greater than 7V
for 1200mS. This indicates there is an open-circuit
between the System Module’s –P terminal and the
pump motor.

• ZAPI - HEALTH (Status LED) - ON

778

TRACTION T HIGH -
CHECK POWER CIR-
CUITS

Drive, Steer, and Lift Prevented

• While driving, the voltage measured at the System

Module’s T terminal did not agree with the predicted
value for at least 300mS. This issue may be caused by
a power wiring error or an internal fault.

• ZAPI - HEALTH (Status LED) - ON

779

TRACTION T LOW -
CHECK POWER CIR-
CUITS

Drive, Steer, and Lift Prevented

• While driving, the voltage measured at the System

Module’s T terminal did not agree with the predicted
value for at least 1000mS. This issue may be caused by
an opencircuit of the armature wiring (+B and –T ter-
minals) or an internal fault.

• VMN does not increase more than 1.3V
• VMN is less than 20% Battery Voltage
• Battery Voltage . VMN is greater than 4V
• ZAPI - HEALTH (Status LED) - ON

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

Advertising
This manual is related to the following products: