JLG 3246ES Service Manual User Manual

Page 150

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

5-30

– JLG Lift–

3121166

5.10

MACHINE CONFIGURATION PROGRAMMING INFORMATION - SEVCON - 1600346

NOTE: When configuring an ES scissors machine, the machine configuration must be completed before any personality set-

tings can be changed. Changing the personality settings first and then changing the model number of the machine con-
figuration will cause the personality settings to return to default.
Shaded entries are not available for the selected Market.

Table 5-5. Machine Configuration Programming Information

(Machines with Sevcon - 1600346 Power Module Only)

Configuration

Digit

Setting

Description

* Market Default Setting

0

1

2

3

4

5

1

(Model #)

1
2
3
4
5

1930ES

2030ES

2630ES

2646ES

3246ES

(Set to your applicable ES Model

1 through 5)

2

(Market *)

0
1
2
3
4
5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0 - (ANSI USA)

(Set to your applicable market)

3

(Tilt Cutout)

0
1

NO - Drive and lift up not prevented while tilted (Ground and Platform Mode).
YES - Drive and lift up prevented while tilted (Ground and Platform Mode).

1

1

1

0

1

1

4

(Drive Cutout)

0
1

No - Drive and lift up not prevented while elevated.
Yes - Drive and lift up prevented while elevated.

0

5

(Charger Interlock)

0

1

DRIVE ONLY - Drive motion prevented while vehicle is charging.
Drive and Lift Up - Drive and lift up motions are prevented while vehicle is charging.
Required for CE.

0

0

0

0

0

0

6

(Ground Alarm)

0

1

2

NOT INSTALLED - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled, and as a horn.
DESCENT - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS enabled,
as a horn and during Lift Down motion.
MOTION - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS enabled,
as a horn and during Drive and Lift motion.

2

2

2

0

2

2

7

(LSS -

Load Sensing

System)

0
1

2

NOT INSTALLED - Load Sensing System (LSS) is not fitted to the vehicle.
CUTOUT PLT - Load Sensing System (LSS) is fitted and Platform Controls are prevented in
the event of an Overload. Ground Controls remain functional. This is the default setting for
CE machines.
CUTOUT ALL - Load Sensing System (LSS) is fitted. Platform and GRound Controls are pre-
vented in the event of an overload.

0

1

0

1

0

1

8

(Drive Motors)

0
1

PEERLESS - Vehicle is fitted with Peerless drive motors.
ADVANCED DC - Vehicle is fitted with ADvanced DC drive motors.

1

9

(Elev Prox)

0

1

NOT INSTALLED - Vehicle is not fitted with an Elevation Prox Sensor. Vehicle has Left and
Right Brake Release Outputs, and Maintained Brake Release functionality.
INSTALLED - Vehicle is fitted with an Elevation Prox Sensor (original ES-Series). Vehicle has
a single Brake Release Output, and Momentary Brake Release functionality.

0

10

(Battery)

0
1

FLOODED - Batteries are conventional lead-acid type.
AGM - Batteries are absorbed glass mat type.

0

11

(Footswitch)

0
1

NO - Vehicle is not fitted with a footswitch
YES - Vehicle is fitted with a footswitch

0

0

0

0

0

1

4150473-F

Advertising
This manual is related to the following products: