SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-8

– JLG Lift –

3121166

2232 FUNCTION PROBLEM -

DRIVE & LIFT BOTH
OPEN

The drive and lift inputs are both
de-energized in Platform Mode.

• Check if either function is active, if Yes;
• Repair the wiring or switch to clear the message.
• ZAPI - HEALTH (Status LED) - ON

2-3 Ground Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

231

FUNCTION PROBLEM -
LIFT PERMANENTLY
SELECTED

The ground control box lift
switch was closed up or down,
during power-up in ground
mode.

• Check if the lift switch is obstructed or jammed.
• Check the lift switch signal and wiring to the ground

board. The lift switch input (24V) is from ground
board terminal J2-4, and its outputs (24V when
closed) are to ground board terminals J2-6, J2-7 (up
and down).

• Replace ground board.

232

GROUND LIFT UP /
DOWN ACTIVE
TOGETHER

The lift up / down inputs are
closed simultaneously.

• Check if the lift switch is obstructed or jammed.
• Check the lift switch signal and wiring to the ground

board. The lift switch input (24V) is from ground
board terminal J2-4, and its outputs (24V when
closed) are to ground board terminals J2-6 (up), J2-7
(down).

• Replace ground board.

233

FUNCTION PROBLEM -
BRAKE RELEASE PERMA-
NENTLY SELECTED

The manual brake release switch
was closed during power-up.

• Check if the brake release switch is obstructed or

jammed.

• Check the brake release switch signal and wiring to

the ground board. The brake release switch input
(24V) is from ground board terminal J1-19, and its out-
put (24V when closed) is to ground board terminal J1-
20.

• If the brakes are released, the machine can be pushed

or moved without drive motor power.

• Replace ground board.

2-5 Function Prevented

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

251

ELEV ANGLE SENSOR
FAULTY - VOLTAGE OUT
OF RANGE

The elevation angle sensor
input voltage is outside the
acceptable range of 0.10V -
4.50V.

• Check that the platform elevation sensor is securely

mounted and undamaged.

• Check voltage as displayed on ANALYZER -> DIAG-

NOSTICS -> ELEV SENSOR -> ANGLE SNSR. Backprobe
ground board J1-15. If this voltage disagrees with the
ANGLE SNSR voltage, replace the ground board.

• Backprobe the elevation angle sensor connector. Ter-

minal A should be 4.7V, terminal C should be 0V.

• Check the elevation angle sensor signal and wiring to

the ground board. The elevation angle sensor input is
from ground board terminal J1-14 (4.7V), its output
(0.1 - 1.2V when stowed) is to ground board terminal
J1-15, and its ground is to ground board terminal J1-
16.

• Replace the ground board.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

Advertising