Caron 6017 User Manual

Page 66

Advertising
background image

6010 Series Operations Manual

Rev E 2/14/2012

Page 66 of 68

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 2

P1

2

Soak step type

S.tyP

SoAH

Time in hours

hoUr

2

Time in minutes

Min

30

Time in seconds

SEC

0

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 3

P1

3

Rate step type

S.tyP

rAtE

Target set-point (50ºC)

T9.SP

50

Ramping rate (1ºC per minute)

rAtE

1

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 4

P1

4

Soak step type

S.tyP

SoAH

Time in hours

hoUr

8

Time in minutes

Min

0

Time in seconds

SEC

0

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 5

P1

5

Jump loop step

S.tyP

JL

Jump step (go to step 1)

JS

1

Jump count (repeat 6 times)

JC

6

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 6

P1

6

Timed step type

S.tyP

ti

Target set-point (30ºC)

T9.SP

30

Time in hours

hoUr

1

Time in minutes

Min

30

Time in seconds

SEC

0

Event Output 1

Ent1

oFF

Event Output 2

Ent2

oFF

Step 7

P1

7

Advertising
This manual is related to the following products: