Environmental conditions, Control specifications, Current loop – ElmoMC Gold Line Digital Servo Drives-Gold Drum HV User Manual

Page 88

Advertising
background image

Gold Drum HV Installation Guide (EtherCAT and CAN)

Technical Specifications

MAN-G-DRUMHVIG-EC (Ver. 1.202)

|

www.elmomc.com

88

Table of Contents

5.2. Environmental Conditions

Feature

Details

Ambient operating temperature

0 °C to 40 °C (32 °F to104°F)

Storage temperature

-20 °C to 85 °C (-4 °F to 185 °F)

Maximum Altitude

2,000 m (6562 feet)

Maximum non-condensing humidity

90%

Protection level

IP32

5.3. Control Specifications

5.3.1.

Current Loop

Feature

Details

Controller type

Vector, digital

Compensation for bus voltage variations

“On-the-fly” automatic gain scheduling

Motor types

AC brushless (sinusoidal)

DC brushless (trapezoidal)

DC brush

Linear motors

“Voice” coils

Current control

Fully digital

Sinusoidal with vector control

Programmable PI control filter based on a

pair of PI controls of AC current signals

and constant power at high speed

Current loop bandwidth

> 4 kHz closed loop

Current sampling time

Programmable 40 to 120 µsec

Current sampling rate

Up to 20 kHz; default 20 kHz

Advertising