Digital output interface – a mode, Analog input – ElmoMC Gold Line Digital Servo Drives-Gold Drum HV User Manual

Page 98

Advertising
background image

Gold Drum HV Installation Guide (EtherCAT and CAN)

Technical Specifications

MAN-G-DRUMHVIG-EC (Ver. 1.202)

|

www.elmomc.com

98

Table of Contents

5.5.5.

Digital Output Interface – A Mode

Feature

Details

Option applicable

A

Type of output

Optically isolated Sink

Maximum supply output (VDD)

30 V

Max. output current
I

out

(max) (V

out

= Low)

I

out

(max) ≤ 300 mA for Output 1

I

out

(max) ≤ 150 mA for Outputs 2 to 4

VOL at maximum output voltage
(low level)

V

out

(on) ≤ 0.3 V

R

L

The external R

L

must be selected to limit output

current to no more than 300 mA (Output 1) or
150 mA (Outputs 2 to 4).

Executable time

0 < T < 250 µsec

Figure 46: Digital Output Schematic for A Option

5.5.6.

Analog Input

Feature

Details

Maximum operating differential voltage

± 10 V

Maximum absolute differential input voltage

± 16 V

Differential input resistance

3.74 kΩ

Analog input command resolution

14-bit

Advertising