Digital Output Panel

Defines digital output actions.

Note:

Only digital output resources in which the source type is User, Action, Application, or Action or Application
are displayed.

Description

Item

Sets the pulse duration time for digital outputs with a pulse option.

Pulse Width

Identifies the digital output.

Signal

Defines the digital output signal’s behavior:

Options

Disabled—No signal.

Set—The signal offers no electrical resistance and allows current flow.

Clear—The signal offers infinite electrical resistance and prevents current
flow.

Toggle—The signal inverts its present state (from low-to-high or
high-to-low).

Pulse—The signal inverts its present state with a pulse signal, holds the
inverted state for the time specified in the Pulse Width control, and then
returns to its original state.

Delay action

Select Delay in the navigation pane to display controls to define a delaying action.

Note:

The Delay action pertains only to an action-group (see table).

Description

Item

Sets the delay time between individual actions in an action-group.

Time

Action-Group

Select Action-Group in the navigation pane to display controls to create a single action that combines individual
actions.

An action-group can include the standard actions (Indicate, Station Power Off, Interlock, Program Interlock,
Program Stop, and Program Hold actions), User-Defined actions, and Delay actions.

Description

Item

Lists the user-defined and standard actions that can be combined into an
action-group.

Available

Lists the actions that have been added to the action-group.

Included

Moves the selected Included action up one place in the list.

164 MTS Series 793 Control Software