MTS Series 793 User Manual

Page 256

Advertising
background image

Item

Callout

Function Generator (or Drive File)

1

Desired

2

Compensation Filter

3

Drive

4

Test System

5

PID Controller

6

Actuator

7

LVDT

8

Position Feedback

9

Inverse System Identifier

10

Response

11

AIC Tab Settings

Description

Item

Sets how quickly compensation values are applied to converge the feedback
and command signals.

Convergence Rate

Sets a time delay between the desired and response signals.

Anticipation

Sets the length of the adaptive filter, which influences how completely the
dynamics of the controller/actuator/specimen combination are cancelled.

Impulse Response

Sets the crossover frequency.

Crossover Freq

When applying AIC to a dual compensation mode configured in the Station
Builder application for Amplitude Control Only, set this control to 0.

Allows the selection of a required type of pre-emphasis filter.

Pre-emphasis Filter

256 MTS Series 793 Control Software

Station Setup

Advertising