MTS Series 793 User Manual

Page 326

Advertising
background image

Note:

The Function Generator does not recognize Program Hold or Program Hold Interlock, but instead goes
to Stop.

Warning:

Changes in Function Generator values made with hydraulic pressure on can result in unexpected
actuator movement.

A moving actuator can injure anyone in its path.

Always clear the actuator area before changing values.

Function Generator Control Panel

Description

Item

Selects the control channel.

Channel

Click the Channel button to toggle between individual channels and
a Master Command Group.

Selecting a Master Command Group blanks out the Control Mode
and Active Mode entries.

Sets the control mode used when the Function Generator starts.

Control Mode

326 MTS Series 793 Control Software

Using Station Manager to Run Tests

Advertising