MTS Series 793 User Manual

Page 76

Advertising
background image

Description

Callout

Command

2

PIDF

3

Valve Driver

4

Conditioner

5

Drive

6

Feedback

7

Load Frame/Actuator

8

Program with feedback channels

Program with feedback channels are used to program external controllers while monitoring feedback for
command compensation or data acquisition. In this channel configuration, the external controller maintains
closed-loop control.

Description

Callout

Controller

1

Command

2

Feedback

3

External Controller

4

PID

5

Drive

6

Program only channels

Program only channels are used to send programming to an external controller. In this channel configuration,
the external controller maintains closed-loop control.

76 MTS Series 793 Control Software

Station Builder