Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual

Page 102

Advertising
background image

Programming

5-34

Feature Select Group

(continued)

[S Curve Time]

Parameter # 56

Factory Default 0.0 Sec

[S Curve Time]

Parameter Type Read & Write

Minimum 0.0 Sec

This parameter enables an adjustable shape S-Curve
accel/decel time. Important: [S-Curve Time] must be set
to a value less than or equal to the Accel & Decel times.

Units 0.1 Second

Maximum 300.0 Sec

a

'

1/2

S-Curve

Time

Decel Time

1 or 2

Accel Time

1 or 2

Figure 5.17 S-Curve Time

Enabled

Disabled

[S-Curve Enable] must be ‘‘enabled” for this
parameter to be active. The [S-Curve Time] setting
is added to the active accel/decel times to form an
adjustable S-Curve.

Important: If [Stop Select] is set to “S Curve”
then the decel time will be double the active decel
setting when a stop command is provided.

a

'

a

'

a

'

1/2

S-Curve

Time

1/2

S-Curve

Time

a

'

1/2

S-Curve

Time

a

'

[Language]

Parameter # 47

Factory Default Alternate language in multilingual versions,English in English only

[Language]

Parameter Type Read & Write

Alternate language in multilingual versions,English in English only
versions.

This parameter selects between English and the alternate
second language that can be displayed on the HIM.

Units Text

Settings ‘‘English” or

“French”
“Italian”
“Spanish”
“German”

Advertising