Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual

Page 126

Advertising
background image

Troubleshooting and Fault Information

6-2

Table 6.A Fault Code Cross Reference

Fault Number

Fault Name

Page

F3
F4
F5
F6
F7

Power Loss Fault
Undervolt Fault
Overvolt Fault
Motor Stall Fault
Overload Fault

6-7
6-8
6-6
6-5
6-6

F8
F9
F10
F11
F12

Overtemp Fault
Open Pot Fault
Serial Fault
Op Error Fault
Overcurrent Flt

6-6
6-5
6-7
6-5
6-6

F22
F24
F25
F26
F29

Drive Reset Flt
Motor Mode Flt
Overspeed Flt
Power Mode Fault
Hz Err Fault

6-3
6-5
6-6
6-7
6-3

F30
F32
F33
F34
F35

Hz Sel Fault
EEprom Fault
Max Retries Fault
Run Boost Fault
Neg Slope Fault

6-3
6-3
6-4
6-7
6-5

Fault Number

Fault Name

Page

F36
F38
F39
F40
F41

Diag C Lim Flt
Phase U Fault
Phase V Fault
Phase W Fault
UV Short Fault

6-3
6-6
6-6
6-6
6-8

F42
F43
F44
F45
F46
F48

UW Short Fault
VW Short Fault
IPM Current Fault
IPM Overtemp Fault
Power Test Fault
Reprogram Fault

6-8
6-8
6-4
6-4
6-6
6-7




Drive

→ HIM➀

HIM

→ Drive➀

Network Error

✳ ➀

Pin ID Error

6-3
6-4
6-5
6-7

These faults are generated in the HIM and not stored in the drive EEPROM.