Rockwell Automation 1305 AC Drive, Series C, Firmware 6.xx and Up User Manual

Page 77

Advertising
background image

Programming

5-9

Setup Group

(continued)

[Accel Time 1]

Parameter # 7

Factory Default 10.0 Sec

[Accel Time 1]

Parameter Type Read & Write

Minimum 0.0 Sec

This parameter is the factory default parameter for
determining the time it will take the drive to ramp from 0 Hz
to [Maximum Frequency]. The rate is linear unless
[S Curve] is ‘‘Enabled.” It applies to any increase in
command frequency. The [Accel Time 2] parameter can
be selected in place of this parameter. (See Chart on Page
5-30).

Units 0.1 Second

Maximum 3600.0 Sec

[Decel Time 1]

Parameter # 8

Factory Default 10.0 Sec

[Decel Time 1]

Parameter Type Read & Write

Minimum 0.0 Sec

This parameter is the factory default parameter for
determining the time it will take the drive to ramp from
[Maximum Frequency] to 0 Hz. The rate is linear unless
[S Curve] is ‘‘Enabled” or [Stop Select] is set to
‘‘S-Curve.” It applies to any decrease in command
frequency. The [Decel Time 2] parameter can be selected
in place of this parameter. (See Chart on Page 5-30).

Units 0.1 Second

Maximum 3600.0 Sec

Max. Frequency

'

Accel

Time

'

a

Decel

Time

a

'

Speed

Time

0

0

Figure 5.1 Accel/Decel Time