Programming

5-20

Advanced Setup Group

(continued)

[PWM Frequency]

Parameter # 45

Factory Default 4.0 kHz

[PWM Frequency]

Parameter Type Read & Write

Minimum 2.0 kHz

This parameter sets the carrier frequency for the PWM
output waveform.

Important: Output Current derating applies above 4kHz.
See Fig. 5-11.

Important: Changing PWM carrier frequency may result in
changes in Start-up and Holding current if start boost and
DC Holding voltages are in effect. These parameters
should be checked if the carrier frequency is changed and
reprogrammed if needed.

Units 0.1 kHz

Maximum 8.0 kHz

Figure 5.11 PWM Frequency Derating

1

2

3

4

5

6

7

8

84

86

88

90

92

94

96

98

100

% Output Current (A)

Carrier Frequency, kHz

Important: Ignoring derating guidelines can
cause reduced drive performance.