DATAVIEW Software

For each selected harmonic data type, you can choose a range of harmonics to

record from the 1st to 50th. You can further limit that range to only include odd

numbers by checking the box for Odd Harmonics Only.

End Recording: Ends any recording in progress or any future recording.
Clear Entries: Clears the data entered in the new recording window. It

does not cause any changes to the PowerPad unit.

Write Changes and Start New Recording: Causes the PowerPad unit to

schedule a new recording.
The PowerPad unit loses its scheduled memory if it is powered off before

the recording begins. If it is powered off during the recording, a partial

recording will usually still exist but with the first letter of its name changed

to @. The start and end times requested for the recording might be

adjusted by the PowerPad unit to be in even multiples of the averaging

period. For instance, if an integration period of 10 minutes were requested,

and the start time was 9:03, the recording might not actually begin until

9:10.
If Ok or Apply is pressed, the following screen appears.

Click Yes to schedule a recording, click No to return you to the Configure

dialog box without starting a recording.