Safety Specifications

1200 Amp AC Current Probe

(Base Unit Accuracy Included)

Attribute

1412-PP2127

Electrical Safety (per EN 61010-1)

Double insulation

600V rms, Category IV, Pollution Degree 2

Electromagnetic Compatibility

Immunity and Emission

EN 61236-1 amendment 1

Electrostatic Discharges

IEC 1000-4-2

Radiation Field Resistance

IEC 1000-4-3

Fast Transients Resistance

IEC 1000-4-4

Electric Shock Resistance

IEC 1000-4-5

Conducted RF Interference

IEC 1000-4-6

Mechanical Protection

Shock and Vibration

EN 61010-1

IP 50

EN 60529 (electrical IP2X for the terminals)

Attribute

1412-PP2137-02

Nominal Range

1000 A AC for f  1 kHz

Measurement Range

3 A … 1200 A AC max (I > 1000 A not continuously)

(1)

(1) Currents < 0.5 A are displayed as zero on the PowerPad unit with this probe.

Probe Output Signal

1 mV AC/A AC

Maximum Clamping Diameter

52 mm (2 in.)

Safety

EN 61010-2-032, 600V, Category IV, Pollution Degree 2

Attribute

1412-PP2137-02

Ambient temperature

23 °C (73 °F) ± 3 °C (5 °F)

Humidity

20 … 75% of RH

Frequency

48 … 65 Hz

Distortion factor

< 1% no DC current

Magnetic field of external origin

< 40 A/m (earth's magnetic field)

Primary current

(A ac)

3 … 10 A

10 … 100 A

100 … 1200 A

Accuracy (% of the output

signal)

 0.8% ± 1 ct

 0.3% ± 1 ct

 0.2% ± 1 ct

Phase shift (°)

 1 °

 0.5°

 0.3°