Rockwell Automation Publication 2711P-UM006C-EN-P - April 2013

13

Overview

Chapter 1

Start-up Options

You can configure the terminal to perform one of three actions at startup:

Launch a FactoryTalk View Machine Edition HMI application.
Launch the FactoryTalk View Machine Edition Configuration mode of

the terminal where you load and run applications, configure start-up
options and terminal settings, and enable or disable desktop access.

Launch the Windows Explorer desktop.

The factory default state and start-up option following a firmware upgrade is to
launch the terminal in Configuration mode. Refer to

Start-up Options on

page 51

for details on how to change the start-up option.

Desktop Access

Any of the terminals can be configured to allow or restrict desktop access. From
the desktop, you can perform system and control panel operations, or run
third-party applications. Terminals with optional, extended features (catalog
numbers ending in 9) can additionally run viewers, media players, and launch the
web browser. You can even allow access temporarily to perform specific tasks,
then disable desktop access to prevent unauthorized changes.

Refer to

Desktop Access on page 54

for details on how to modify desktop access.

Software Support

The table lists software supported on the terminals.

TIP

All terminals are initially shipped with desktop access disabled.

IMPORTANT

Desktop access does not change the feature set of your terminal. If you have a
terminal with a catalog number ending in 8, opening the desktop does not
give you access to extended features and file viewers.

Table 2 - PanelView Plus 6 Software Support

Software

Description

Version

FactoryTalk View Machine Edition Station

Runtime environment for FactoryTalk View Machine Edition .mer applications. Machine Edition
Station is preloaded on each terminal and does not require FactoryTalk View activation.

6.10 or later

(400 and 600 terminals)

6.0 or later

(700 to 1500 terminals)

FactoryTalk View Studio for
Machine Edition

Configuration software for developing HMI applications that run on PanelView Plus 6 terminals.
RSLinx

®

Enterprise software is included with FactoryTalk View Studio software and loaded during

installation.

FactoryTalk ViewPoint
(700 to 1500 terminals only)

Add-on capability provided with FactoryTalk View Studio software:
This web-based, thin-client solution lets manufacturers or casual users monitor or download

changes to a running Machine Edition application from remote locations via an Internet
browser.

A single license is embedded with each terminal supporting a single client connection to

terminal. No additional software is required.

1.2 or later

Windows CE 6.0 OS

Operating system that runs on all terminals.

6.0