Configuration Mode

Chapter 3

Start-up Options

You can specify what action the terminal takes on startup or a reset.

Disable FactoryTalk View ME Station Software on Startup

Terminals with extended features and file viewers are typically configured to
launch the Windows desktop on startup. This means you must disable
FactoryTalk View ME Station from launching on startup.

Follow these steps to disable FactoryTalk View ME Station on startup so that the
desktop can launch.

1. Press Terminal Settings>Startup Options.

2. Press On Startup until ‘Do not start FactoryTalk View ME Station’ is

selected.

3. Press OK.

This Start-up Option

Performs This Action

Typical System

Do not start FactoryTalk View ME
Station

Launches the Windows Explorer desktop on startup.

Open

Go to Configuration Mode

Launches FactoryTalk View ME Station Configuration
mode on startup. This is the initial, factory default setting.

Closed

Run Current Application

Runs the FactoryTalk View ME application loaded in the
terminal on startup.

Closed

IMPORTANT

When desktop access is restricted, the start-up option must be set to Run
Current Application or Go to Configuration Mode (default). Refer to

page 54

for

details on how to enable or disable desktop access.

TIP

The desktop can also be launched from FactoryTalk View ME Station
Configuration mode by pressing Exit.

TIP

When disabling FactoryTalk View ME Station, desktop access must be set to
allow or you get a warning. Refer to

Enable Desktop Access on page 54

.