5. Carefully lift the logic module away from the terminal and turn over to

expose the circuit board.

6. Locate the battery on the circuit board.

7. Remove the battery by lifting up the side of the battery.

The battery can be removed up to 15 seconds without losing clock and
calendar data.

8. Insert the new battery.

9. Reattach the logic module by aligning the two connectors on the bottom

of the logic module with the connectors on the back of the display module.

10. Push down on the logic module until it is firmly seated.

11. Tighten the four captive screws that secure the logic module to a torque of

0.58 N•m (5…7 lb•in).

12. Reattach the communication module, if necessary, and tighten the four

screws to a torque of 0.58 N•m (5…7 lb•in).

Install the AC Power Supply
Module

The AC power supply module for the 400 and 600 terminals, catalog number
2711P-6RSA, attaches to the back of a DC-powered terminal to convert the
terminal from DC to AC power. You can install the AC module with the
terminal mounted in the panel. No special tools are needed.

Follow these steps to attach and wire the AC power module.

1. Disconnect power to the terminal.

2. Remove the DC power terminal block currently installed in your terminal.

See

Remove and Install the Power Terminal Block on page 37

.

Advertising