78 Specifications

Inputs

6 Channels

Transducer Power

Voltage Range

Sensitivity

Input Impedance

Discrete Switch

(XM-161 and XM-162 only)

Eddy current transducer signals
IEPE Accelerometer signals
Voltage signals from any dynamic
measurement device, such as a velocity or
pressure transducer

IEPE constant current (2.69mA ±20% from
+24V dc)
None (voltage input)
Constant voltage (-24V dc) (XM-162 only):
max 20mA per channel

±24V dc
6.5V peak-to-peak

User configurable in software

Greater than 100k

Relay reset and Setpoint multiplier
functions
Non-isolated switch input: switch to ground
(24V COM)
Max nominal sourced current (circuit
limited): 5.1mA

Buffered Outputs

Number

Range Configurable in Software

Output Impedance

Response

1 active buffer per vibration input channel

All channels negative (-22V dc to +3V dc) or
positive (+0.6V dc to +22V dc)

500 ohms

-3dB @ 16kHz (down 5% @ 5kHz)

4-20mA Outputs (XM-161 only)

Number

Accuracy

Response Time (3 tau)

Two isolated banks of three outputs (one
per channel)
600 ohm max load (24V loop power)
Outputs proportional to overall value
Non-powered (external loop voltage
required, 7 to 36V)

Max: ±0.5% of full scale
Typical: ±0.2% of full scale

1.5 seconds

XM-160/161/162 Direct Vibration Technical Specifications