Rockwell Automation 1440-VDRP06-00RH XM-160/161/162 Direct Vibration Module User Manual

Page 88

Advertising
background image

Publication GMSI10-UM025C-EN-P - August 2010

80 Specifications

Trend Buffer

Number or Records

Time Interval

Trigger

Post Trigger

Capacity

1 to 12 parameters

1 to 3600 seconds

Relay on the XM-441 Expansion Relay
module is activated, or by a trigger event
(for example, DeviceNet command from a
controller or host).

The data collected in the buffer is user
configurable in software.

Percent of trend that is to be acquired after
the trigger

170 to 2048 records

Alarms

Number

Operators

Hysteresis

Startup Inhibit

One per channel

Greater than
Less than
Inside range
Outside range

User configurable in software

Period: 0 to 1092 minutes, adjustable in 0.1
minute increments
Inhibit/multiplication function: Multiply by
N (0 to 10, 0 = Disarm)
Inhibit/multiplication initiated by:

DeviceNet command
Front terminal Setpoint Multiplier circuit
closure (XM-161 and XM-162 only)

Inhibit/multiplication terminated by:

Expired timer
DeviceNet command
Front terminal Setpoint Multiplier circuit
open (XM-161 and XM-162 only)

XM-160/161/162 Direct Vibration Technical Specifications

Product Feature

Specification