Specifications 79

Indicators

8 LEDs Module Status - red/green

Network Status - red/green
Channel 1 Status - yellow/red
Channel 2 Status - yellow/red
Channel 3 Status - yellow/red
Channel 4 Status - yellow/red
Channel 5 Status - yellow/red
Channel 6 Status - yellow/red

Vibration Measurement & Signal
Conditioning

A/D Conversion

Resolution

Accuracy

Units

Range

Low Pass Filter

High Pass Filter

Additional Overall Low Pass Filter

Integrator

Overall Level

12 bits

0.05% of full scale

Max: ±5% of full scale 3Hz to 1kHz,
+5/-10% 1kHz to 5kHz
Typical: ±1% of full scale

volts g
ips mm/s
mils um
psi Pa

0 to 2ips RMS (integrated 100mV/g accel @
1kHz), 0 to 20g RMS (100mV/g accel), 0 to
15.6mils peak (200mV/mil probe)

1kHz or 5kHz selectable, 2-pole 0.1dB
Chebyshev (-0.1dB @ fo)

3.0Hz or 10.0Hz selectable, 2-pole 0.1dB
Chebyshev (-0.1dB @ fo)

Single pole, -3dB @ 10kHz (down 10% @
5kHz)

Single stage selectable, -0.3dB @ 3Hz

RMS
Peak (true or calculated)
Peak to Peak (true or calculated)

DC Bias (Gap) Voltage
Measurement

Low Pass Filter

Range

Accuracy

Resolution

Single pole, -3dB @ 335Hz

-24V dc to +24V dc

Max: ±5% of full scale (48V dc)
Typical: ±1% of full scale

47mV

XM-160/161/162 Direct Vibration Technical Specifications

Product Feature

Specification