Rockwell Automation 1440-SPD02-01RB XM-220 Dual Speed Module User Manual

Page 75

Advertising
background image

Publication GMSI10-UM004B-EN-P - May 2010

Specifications 67

Measured Parameters

Direction

Speed

Acceleration

Peak Speed

Gap (or transducer bias voltage)

Measured Units

Forward
Reverse

RPM
Direction of Rotation
Acceleration in RPM / Minute

Measurement Modes

Dual Channel

Single Redundant Channel

Reverse Rotation

Two sensors are used independently to
perform two separate speed, acceleration
and peak speed measurements.

One sensor is used to perform the speed,
acceleration and peak speed
measurements. If the current sensor fails,
the module automatically switches to the
second (redundant) sensor.

Two sensors are used to monitor both speed
and direction. The two sensors must be
mounted out of phase from each other so
that the rotational direction can be
determined by monitoring which sensor the
shaft keyway passes first.

Alarms

Number

Alarm Parameters

Operators

Hysteresis

8 alarms, fixed per channel

Alarm and danger pair provided for each of:
Speed
Acceleration
Zero Speed
Locked Rotor

Greater than
Less than
Inside range
Outside range

User configurable in software

XM-220 Technical Specifications

Product Feature

Specification

Advertising