Services, Discrete input point object (class id 08h), Class attributes – Rockwell Automation 1440-SPD02-01RB XM-220 Dual Speed Module User Manual

Page 99: Discrete input point object (class id 08

Advertising
background image

Publication GMSI10-UM004B-EN-P - May 2010

DeviceNet Objects 91

Services

Discrete Input Point Object
(Class ID 08

H

)

The Discrete Input Point Object Instance 1 indicates whether the module is
in the startup period. Instance 2 indicates whether the machine is rotating in
the reverse direction.

Class Attributes

14

Get

Produced Connection
Path

Array of
USINT

Specifies the Application Object(s) whose
data is to be produced by this Connection
Object. See DeviceNet Specification
Volume 1 Appendix I.

15

Get

Consumed Connection
Path Length

UINT

Number of bytes in the
consumed_connection_path attribute.

16

Get

Consumed Connection
Path

Array of
USINT

Specifies the Application Object(s) that are
to receive the data consumed by this
Connection Object. See DeviceNet
Specification Volume 1 Appendix I.

17

Get

Production Inhibit Time

UINT

Defines minimum time between new data
production.

Table C.17 Connection Object Instance Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Table C.18 Connection Object Services

Service
Code

Class/Instance Usage

Name

05

h

Instance

Reset

0E

h

Instance

Get_Attribute_Single

10

h

Instance

Set_Attribute_Single

Table C.19 Discrete Input Object Class Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Semantics

1

Get

Revision

UINT

Revision of the
implemented object.

2