AJA FS1 User Manual

Page 18

Advertising
background image

10

If the temperature threshold is exceeded inside the FS1, the lower line of the
power/temperature status display will read “OVERHEATED”. This is an
indication that video output may be compromised. Please note, that if the Alarm
LED is lit on the front panel, the reason should be evident after examining the
video format status screen and the power/temperature status screen.

The fourth screen is a close-captioning status screen showing whether Closed
Caption data is present on the selected Video Input.

The fifth status screen is a scrolling AJA Logo. This same scrolling logo will be
displayed when no button activity has been detected for 60 minutes.

The sixth status screen is the FS1’s System Name as has been previously defined
(the System Name and how to enter/edit it is described later in Chapter 4,
Parameter Menus, System Name 50.5).

Controlling the
FS1 Using the
Select and Adjust
Buttons

The FS1's Control system is designed to be easy to operate and remember. All
functions in the menu system are numbered for easy reference. There are two sets
of up/down buttons, Select and Adjust:

To operate the FS1, one merely selects a function/parameter with the Select
buttons, and then adjusts the selected function/parameter with the Adjust
buttons.

The Control Display has two lines:

The top line contains a numbered and named FS1 parameter and or function.
The lower line contains the current setting.

The parameter Select buttons select a parameter to view or modify. Pressing one of
the parameter Adjust buttons changes the current parameter's value to a new one
from the FS1's list of choices—repeating the list if you continue to press Adjust-or
adjusting a numerical value up or down. The exact choices displayed will vary
depending on the Parameter. Adjustment choices made with the Adjust buttons
take effect immediately (except 1.1 Output Format which has a 1/2 second delay).
In most cases, changed parameters will be subsequently stored into the FS1s non-
volatile memory after it remains unchanged for 3 seconds. The exceptions to this
are the IP Address, IP Config, Subnet Mask and all SNMP parameters: for these
you must exit the selection after making changes to activate the changes.

If a Select or Adjust button is held down continuously, the changes will begin to
happen automatically - with acceleration if applicable.

Pressing either a Select or Adjust button-while on the Status or Screen Saver
displays-changes the display to the last remembered Control menu.

Parameter Number and Name

Current Parameter Setting

Select Adjust