3 reference alarm 70.1 screen saver, 3 reference alarm, 1 screen saver – AJA FS1 User Manual

Page 74

Advertising
background image

66

60.3 Reference Alarm

This parameter controls how the FS1 responds to various reference video signal
conditions. When set to Normal, the alarm will trigger when:

1. the reference signal is incompatible with the selected output format or is not

detected at all.

2. the reference signal is required, due either to 1.1 Output format set to “Follow

Ref” or 6.1 Genlock Source set to “Reference.”

If you want the FS1 alarm to only trigger on hardware failures, then suppress the
format alarm.

70.1 Screen Saver

When set to “AJA Logo”, a rolling AJA logo screen saver will appear on the
alphanumeric display after 60 minutes of inactivity—defined as no button presses
on the front panel. If disabled, then the display just becomes dim. When the Screen
saver is on, the STATUS button will return the display to the last Status display, or
any Select or Adjust button will return the display to the last Parameter menu.

60.2 Format Alarm

Description of Choices

Parameter Adjustments:

Normal

(default)

Suppress

Alarm triggers if the format of the selected input video signal is incompatible with
the selected output format.

Alarm will not be triggered by a format incompatibility.

60.3 Reference Alarm

Description of Choices

Parameter Adjustments:

Normal

(default)

Suppress

Alarm triggers if either internal power supply experiences a failure or is
disconnected from mains power.

Alarm will not be triggered by a power supply failure or disconnection from power.

70.1 Screen Saver

Description of Choices

Parameter Adjustments:

AJA Logo

(Default)

System Name

Disabled

Display horizontally rolling AJA logo after 60 minutes of button inactivity
Display the FS1 system name (defined in parameter 50.5).
Dim display after 60 minutes of button inactivity

Advertising