Components and Specifications

2.3 Cordsets

Machine interface cordsets provide power to the first emitter/

receiver pair. Sensor interconnect cables provide power to

subsequent emitters and receivers in the cascade. Only cordsets

with yellow PVC cable and black overmolds are listed; for

cordsets with black PVC cables and overmolds, add suffix “B” to

the model number (e.g.,

RDLP-815DB

).

A removable disconnect (RD) fitting is required to connect

directly to the sensor housing. QD fittings are used for cable-to-

cable interconnections and connections with other devices.

RD to Flying Leads Cordsets

Removable disconnect (RD) connector on one end; unterminated
(cut to length) on other.

Model

Number

Length

Wire

Banner Cordset

Color Code

For Emitters and Receivers

Color Function

RDLP-815D
RDLP-825D
RDLP-850D
RDLP-875D
RDLP-8100D

4.6 m (15.1')
8 m (26.2')
15.3 m (50.2')
23 m (75.5')
30.5 m (100.1')

8-conductor
cable,
22 AWG/
0.33 mm²

Bn

+24V dc

Or/Bk EDM 2 (Aux)
Or

EDM 1

Wh

OSSD 2

Bk

OSSD 1

Bu

0V dc

Gn/Ye Gnd/Chassis
Vi

Reset

RD to Flying Leads Cordsets (E-Stop/Interlock Connections)

Used to connect devices to receiver cascade input RD
connection.
Removable disconnect (RD) connector on one end;
unterminated (cut to length) on other. See Figures 7-8, 7-9, and 7-10.

For Cascade Receivers Only

Color E-Stop

Function

RDLP6G-415D
RDLP6G-425D
RDLP6G-450D

4.6 m (15.1')
8 m (26.2')
15.3 m (50.2')

4-conductor
cable,
22 AWG/
0.33 mm²

Bn

Ch 1a

Wh

Ch 2a

Bk

Ch 1b

Bu

Ch 2b

RD to M12/Euro QD Cordsets

Used to interconnect SLPC.. and SLSC.. (standard EZ-SCREEN)
emitters or receivers in a cascade, or for use with a mating M12/
Euro QD cordset, such as QDE.., DEE2R-.., or CSB-.., listed on
page 10). See Section 7.4 for maximum cascade cordset lengths.

Model

Length

Wire

Termination

DELPE-81D
DELPE-83D
DELPE-88D
DELPE-815D
DELPE-825D
DELPE-850D
DELPE-875D
DELPE-8100D

0.3 m (1')
1 m (3.3')
2.5 m (8.2')
4.6 m (15.1')
8 m (26.2')
15.3 m (50.2')
23 m (75.5')
30.5 m (100.1')

8-conductor
cable,
22 AWG/
0.33 mm²

RD-style
removable
disconnect fitting
at one end, male
M12/Euro QD
fitting at the other

RD to RD Cordsets

Used to interconnect multiple SLPC.. emitters or receivers in a
cascade. See Section 7.4 for maximum cordset lengths.

Model

Length

Wire

Termination

DELP-110E
DELP-111E
DELP-113E
DELP-118E
DELP-1115E
DELP-1125E
DELP-1150E
DELP-1175E
DELP-11100E

0.05 m (0.2')
0.3 m (1')
1 m (3.3')
2.5 m (8.2')
4.6 m (15.1')
8 m (26.2')
15.3 m (50.2')
23 m (75.5')
30.5 m (100.1')

11-conductor
cable,
24 AWG/
0.20 mm²

RD-style
removable
disconnect fitting
at each end,
for cascade
connections
between SLPC..
sensors

RD to Female M12/Euro QD and Mating Cordsets

Used to connect E-stop or other devices to sensor input RD
connection. See Figure 7-8.

Model

Length

Wire

Termination

DELPEF-81D
DELPEF-83D
DELPEF-88D
DELPEF-815D

0.3 m (1')
1 m (3.3′)
2.5 m (8.2′)
4.6 m (15.1′)

8-conductor
cable,
22 AWG/
0.33 mm²

RD-style fitting at
one end, female
M12/Euro QD
fitting at the other
to connect to
QDE2R4-8..D
cordset below

QDE2R4-815D

QDE2R4-825D

QDE2R4-850D

4.6 m (15')

7.6 m (25')

15.2 m (50')

8-pin
connector,
4-conductor
cable,
22 AWG/
0.33 mm²

Male M12/Euro QD
fitting at one end,
flying leads at the
other to enable
4-wire hookup to
device

Figure 2-3. EZ-SCREEN LP connection options

300 mm 8-pin M12/Euro Pigtail QD
Order mating M12/Euro QD cordset
separately: QDE, DEE2R, or CSB (see
page 10)

RD to RD
Requires DELP cordset to connect 2nd,
3rd, and 4th sensors in a cascade (see
Figure 7.8 for other options)

Integral Removable Disconnect (RD)
Requires RDLP, DELPE, or
DELPEF cordset (for cascading)
Cordset sold separately.