Overview, Checkout procedures, 3 shift/daily checkout – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 56: 4 semi-annual (six-month) checkout, Warning

Advertising
background image

54

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

54

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Checkout Procedures

9. Observe the Status indicators and the Diagnostic Display:
Lockout: Status flashing Red

All others OFF

Blocked: Status ON Red

One or more Zone indicators ON Red

Reset ON Yellow

Clear:

Status ON Green*

All Zone indicators ON Green**

Reset ON Yellow

Latch:

Status ON Red

(defined

All Zone indicators ON Green

area clear)

Reset flashing Yellow

* The Status indicator will be flashing Green if reduced resolution is enabled.
** The Zone indicators will be flashing Green if fixed blanking is enabled.

10. A Blocked condition indicates that one or more of the beams

is misaligned or interrupted. To correct this situation see the

Alignment procedure in Section 3.4. If the System is in a

Latch condition, perform a manual reset.

11. Once the Green and Yellow Status indicators are ON,

perform the trip test (described in Section 3.4.4) on each

sensing field to verify proper System operation and to detect

possible optical short circuits or reflection problems. Do not

continue until the EZ-SCREEN LP System passes the trip

test. Do not expose any individual to any hazard during

the following checks.

12. Apply power to the guarded machine and verify that the

machine does not start up. Interrupt (block) the defined area

with the appropriate supplied test piece (see table in Section

3.4.4) and verify that it is not possible for the guarded

machine to be put into motion while any beam is blocked.

13. Initiate machine motion of the guarded machine and, while

it is moving, use the supplied test piece to block the defined

area. Do not attempt to insert the test piece into the

dangerous parts of the machine. Upon blocking any beam,

the dangerous parts of the machine should come to a stop

with no apparent delay.

Remove the test piece from the beam; verify that the

machine does not automatically restart, and that the

initiation devices must be engaged to restart the machine.

14. Remove electrical power to the EZ-SCREEN LP. Both OSSD

outputs should immediately turn OFF, and the machine

should not be capable of starting until power is re-applied to

the EZ-SCREEN LP.

6.3 Shift/Daily Checkout

Perform the procedure contained on the Daily Checkout

card at every shift change, power-up and machine set-

up change. During continuous machine run periods, this

checkout should be performed at intervals not to exceed 24

hours.
A Designated Person or Qualified Person (as defined in the

Glossary) must perform the procedure. A copy of checkout

results should be recorded and kept in the appropriate place

(e.g., near or on the machine, in the machine’s technical file).
Refer to the procedure detailed on the Daily Checkout card

(Banner p/n 140045 for SLP.. stand-alone models, P/N 140046

for SLPC.. cascadeable models) in the lit packet included with

the receiver. If the Daily Checkout card is missing, contact

Banner Engineering or download at

www.bannerengineering.

com

.

6.4 Semi-Annual (Six-Month) Checkout

Perform the procedure contained on the Semi-Annual

Checkout card every six months following System

installation, or whenever changes are made to the System

(either a new configuration of the EZ-SCREEN LP or

changes to the machine).
A Qualified Person (as defined in the Glossary) must perform

the procedure. A copy of checkout results should be recorded

and kept in the appropriate place (e.g., near or on the machine,

in the machine’s technical file).
Refer to the procedure contained on the Semi-Annual

Checkout card (Banner part number 140047) in the lit packet

included with the receiver. If the Semi-Annual Checkout card

is missing, contact Banner Engineering or download at

www.

bannerengineering.com

.

15. Test the machine stopping response time, using an

instrument designed for that purpose, to verify that it is the

same or less than the overall system response time specified

by the machine manufacturer. (Banner’s applications

engineers can recommend a suitable instrument.)

Do not continue operation until the entire checkout

procedure is complete and all problems are corrected.

WARNING . . .

Do Not Use Machine Until

System Is Working Properly

If any of these checks cannot be verified, do not attempt to
use the EZ-SCREEN LP/guarded machine until the defect or
problem has been corrected (see Section 5).
Attempts to use the guarded machine under such conditions
could result in serious bodily injury or death.

WARNING . . .

Before Applying Power to

the Machine

Verify that the guarded area is clear of personnel and
unwanted materials (such as tools) before applying power to
the guarded machine. Failure to do so could result in serious
bodily injury or death.

Advertising