Overview, Installation and alignment – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 30

Advertising
background image

28

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

28

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Installation and Alignment

Fig ure 3-10. Emit ter and re ceiv er mounting hardware (see Appendix A for more information)

Mounting the Side-Mount Brackets

1. From a common point of reference (ensuring the minimum

safety distance calculated in Section 3.1.1), measure to

locate the emitter and receiver in the same plane, with their

midpoints directly opposite each other. Important: The

connector ends of both sensors must point in the same

direction (see Figure 3-5 and warning, Section 3.1.4).

Mount the emitter and receiver mounting brackets to the

desired surface, using the supplied M5 bolts and nuts or

user-supplied hardware; see Figure 3-10.

2. Attach the 2-piece clamp to the sensor housing side

channels (either side of the housing) at the appropriate

locations, using the supplied M3x6 screws.

3. Attach the clamp to the bracket, using the supplied M5

screws.

4. Position the emitter and receiver windows directly facing each

other. Measure from a reference plane (e.g., a level building

floor) to the same point(s) on the emitter and receiver to

verify their mechanical alignment. Use a carpenter’s level, a

plumb bob, or the optional LAT-1 Laser Alignment Tool (see

Section 2.5) or check the diagonal distances between the

sensors, to achieve mechanical alignment; see Figure 3-11.

Final alignment procedures are explained in Section 3.4.

5. Tighten all fasteners.

NOTES:

• EZ-SCREEN LP sensor brackets are designed to mount directly to MSA

Series stands (Section 2.3), using the hardware supplied with the stands.

• See Figure 2-1 for mounting bracket dimensions.

* Emitters and Receivers 830 mm and longer also include an additional side-mount

bracket for center support; sensors 1390 mm and longer include 2 (total 4)

Sensors are designed to be mounted with up to 690 mm unsupported
distance between brackets (see Section 3.2.1).

Side-Mount Brackets

(2 or more*

supplied with each emitter and receiver

)

Sensors may be mounted with all side-mount brackets, or a
combination of side-mount and end-mount brackets.

End-Mount Brackets

(2 supplied with each emitter and receiver)

Bracket

Clamp

360°
Rotation

−30°
rotation

+10°
rotation

Advertising