P/N 133487

59

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

P/N 140044 rev.

E

59

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP
Instruction Manual

Cascadeable EZ-SCREEN

Example 1:
Machine Interface Cordset (L1): 4.6 m (15')
Sensor Interconnect Cordset (L2): 0.3 m (1')
Sensor Interconnect Cordset (L3): 15.2 m (50') or shorter
Sensor Interconnect Cordset (L4): 0.3 m (1')

7.5 Response Time for Cascaded Light Screens

Response time is an important factor in determining a light

screen’s separation (safety) distance. For cascaded (or “daisy-

chained”) EZ-SCREEN LP systems, that response time is

dependent on the number of light screens, the number of beams

in the light screens, and their positions in the cascade. It can be

calculated easily, in two ways:
• Individually for each light screen in the cascade (safety

(minimum) distance is calculated for each light screen in the

cascade), or

• Based on the worst-case time for the entire cascade (where

all light screens in the cascade have the same separation

distance).

Figure 7-4. Cordset length options for four cascaded light screens

Example 2:
Machine Interface Cordset (L1): 4.6 m (15')
Sensor Interconnect Cordset (L2): 0.9 m (3')
Sensor Interconnect Cordset (L3): 15.2 m (50') or shorter
Sensor Interconnect Cordset (L4): 0.9 m (3')

*Multiple DELP..-.. Cordsets may be required.

WARNING . . .

Proper Installation

The user must comply with all instructions within Section 3 for
proper installation. See Sections 7.2 and 3.1.1 for complete
information.

Machine Interface Cordset
(L1) QDE-8..D or RDLP-8..D

0.9 m (3')

4.6 m (15')

7.6 m (25')

Example Cordset pairing per side of cascaded system

Sensor
Interconnect
Cordset
Lengths
(L2, L3 and L4)

L2

L3

L4

L2

L3

L4

L2

L3

L4

Max. L3*

0.3 m

(1')

28 m

(92')

0.3 m

(1')

0.3 m

(1')

20.4 m

(67')

0.3 m

(1')

0.3 m

(1')

13.7 m

(45')

0.3 m

(1')

Individual

DELP-1

1..E

Cordsets

15.2 m

(50')

0.9 m

(3')

15.2 m

(50')

7.6 m

(25')

15.2 m

(50')

7.6 m

(25')

7.6 m

(25')

7.6 m

(25')

7.6 m

(25')

7.6 m

(25')

0.9 m

(3')

7.6 m

(25')

4.6 m

(15')

15.2 m

(50')

4.6 m

(15')

4.6 m

(15')

7.6 m

(25')

4.6 m

(15')

4.6 m

(15')

4.6 m

(15')

4.6 m

(15')

2.4 m

(8')

22.9 m

(75')

2.4 m

(8')

2.4 m

(8')

15.2 m

(50')

2.4 m

(8')

2.4 m

(8')

7.6 m

(25')

2.4 m

(8')

0.9 m

(3')

22.9 m

(75')

0.9 m

(3')

0.9 m

(3')

15.2 m

(50')

0.9 m

(3')

0.9 m

(3')

7.6 m

(25')

0.9 m

(3')

0.3 m

(1')

22.9 m

(75')

0.3 m

(1')

0.3 m

(1')

15.2 m

(50')

0.3 m

(1')

0.3 m

(1')

7.6 m

(25')

0.3 m

(1')

0.1 m

(0.33')

22.9 m

(75')

0.1 m

(0.33')

0.1 m

(0.33')

15.2 m

(50')

0.1 m

(0.33')

0.1 m

(0.33')

7.6 m

(25')

0.1 m

(0.33')

Cascade Cordset Connection Schemes

Optional Connection
DELPEF-81D cordset / DEE2R-8..D cordset (optional) /
DELPE-8..D (or P8 models)

Standard Connection
DELP-8..D cordset

L2

L1

EZ-SCREEN
LP Position
#2

Emitters

Machine
Control

Receivers

L3

EZ-SCREEN
LP Position
#1

EZ-SCREEN
LP Position
#3

L4

EZ-SCREEN
LP Position
#4

Advertising