EZ-SCREEN LP
Instruction Manual

Cascadeable EZ-SCREEN

Remote Fixed Blanking Programming Procedures

Prior to performing these procedures, install the EZ-SCREEN

LP per Section 3 of this document, including all other DIP switch

configuration settings (T/L, RR, and Scan Code). Align the E/R

pair and perform all required checkout procedures to ensure

proper operation. Ensure that the EZA-RBK-1 programming key

switch is rotated to the counter-clockwise position (Run position,

see Figure 7-11) at power-up and normal operation.

Important:
1. The first sensing beam (synchronization beam) at the display

end of the sensor must remain clear.

2. The number and location of blocked beams is indicated by the

receiver’s 7-segment display and the zone indicators. If the

configuration is reliable, this number should not change.

3. A reset switch (e.g., a normally open switch) must be used to

complete some programming procedures below.

Initial programming ― no fixed blanking previously programmed, perform the following:

The following procedures must be completed within 10 minutes or a lockout will occur (Error Code 12 will be displayed).

Action

Indication

Comments

1

Locate the obstruction in the defined
area and secure it.

EZA-RBK-1: OFF
Receiver: number and location of blocked
beams is indicated by the 7-segment
display and the zone indicators.

If the configuration is reliable, this
number should not change.

2

Turn the programming key switch
to the Program position (clockwise)
momentarily (> ¼ second) and then
return to the Run position.

EZA-RBK-1: ON (key in Program position),
then slowly flashes for approximately
5 seconds (key returns to Run position).
Receiver: display indicates “P” “F” “C”

This “teaches” and saves the new
fixed blanking configuration.

3

Trip Output: the OSSDs turn ON.
Latch Output:After the EZA-RBK-1
indicator turns OFF, a valid reset
sequence is required to turn ON the
OSSDs

.

EZA-RBK-1: OFF
Receiver: display indicates normal
operation. (See Section 3.4.3, step 9.)

To change (relocate) or clear (remove) previous fixed blanking, perform the following steps:

The following procedures must be completed within 10 minutes or a lockout will occur (Error Code 12 will be displayed).

Action

Indication

Comments

1

Place the programming key switch in
the Program position (clockwise) until
step 3.

EZA-RBK-1: ON
Receiver: sequences between “P” “F” “A” and
the number of blocked beams

.

EZA-RBK-1 indicator steady ON
indicates program mode.

2

Locate or relocate the obstruction (e.g.
tooling, fixturing, etc.) in the defined
area and secure. If clearing the fixed
blanked area, remove all obstructions.

EZA-RBK-1: ON
Receiver: display sequences between “P” “F”
“A” and the number of blocked beams.

I

f an Error code 12 occurs

(programming time out), go to step #6
below
(do not return the programming
key switch to the Run position at this
time).

3

Return the programming key switch to
the Run position (counter-clockwise)

.

EZA-RBK-1: slowly flashes, approximately 5
seconds
Receiver: display indicates “P” “F” “C”

This saves the new fixed blanking
configuration.

4

Trip Output: the OSSDs turn ON.
Latch Output: After the EZA-RBK-1
indicator turns OFF, a valid reset
sequence is required to turn ON the
OSSDs

.

EZA-RBK-1: OFF
Receiver: display indicates normal operation
if fixed blanking is removed. Otherwise, see
Section 3.4.3, step 9.