Overview

P/N 140044 rev.

E

55

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP
Instruction Manual

Cascadeable EZ-SCREEN

7. Cascadeable EZ-SCREEN LP

7.1 Overview of Cascading

EZ-SCREEN LP emitters and receivers are also available in

cascadeable models. These models can be used as stand-alone

light screens, or can be cascaded up to four pairs in one system;

see Figure 7-1. The cascaded sensor pairs can be any length,

any number of beams, or have different resolutions (i.e., 14 mm

and 25 mm), as long as each emitter matches its own receiver.
NOTE: EZ-SCREEN SLP.. (stand-alone) or 8-pin SLSC..

models can be used as the end sensor pair. EZ-SCREEN

Grid/Point and PICO-GUARD components can not be

interfaced with the cascade input.

The control reliability, installation and alignment, electrical

interface to the guarded machine, initial checkout, periodic

checkout, troubleshooting and maintenance features of

cascadeable models are functionally identical to those of the

standard models.
Electrical connections are made via removable disconnect (RD)

cordsets; see Section 2.3. All receivers in a cascade activate the

same set of OSSD outputs: the OSSDs of the master receiver.
NOTE: In a cascaded system, all receivers are connected

together, and all emitters are connected together.

7.1.1 System Components and Specifications

A multiple-light screen cascaded EZ-SCREEN LP system

includes compatible emitter/receiver pairs (up to four), a

terminator plug (shipped installed on each cascade receiver)

for the last receiver in the cascade, two RD cables or pigtail

cables to interface with the machine and provide power to the

system, and pairs of double-ended (sensor interface) cables to

interconnect the emitters and the receivers in the cascade. (A

“dummy” plug is installed at the cascade end of each emitter.

It is not required for operation, but maintains the emitter’s

IP65 rating.) Additional cordsets may be used to enable QD

connections; see Section 2.3.
The terminator plug (model LPA-TP-1) must be used on the

receiver in a stand-alone system, and on the last receiver in a

multiple-pair cascade, unless an EZA-RBK-1 key switch box or

an RDLP6G-4..D cordset interfaced with an E-stop or other hard

contacts is in place (see Sections 7.8 ― 7.10).
NOTE: The machine interface cable must connect to the sensor

end adjacent to the indicators.

Available single-ended, double-ended, and splitter cordsets are

listed in Section 2.3. Cordset lengths are limited – for both the

machine interface/power cables and the sensor interconnect

cables; see Section 7.4 for more information.

7.1.2 Receiver Display

In Run mode, the 7-segment display will show the following. See

Section 5.1.1 if any indication is flashing.

Clear condition
Latch output operation

Trip output operation

Blocked condition

Number of blocked beams (sequential)

CSSI Input OFF or open
(e.g., “upstream” receiver
is blocked or in lockout)

Solid (not flashing)

Figure 7-1. Multiple cascaded light screens used to guard an

irregular opening in a machine