Installation and Alignment

3.2.2 Mounting the Reset Switch

Mount the reset switch in a location that complies with the warning

in Section 3.1.3. See Figures 3-23 through 3-26 for electrical

connection.

3.2.3 Routing Cables

Attach the required cordsets to the sensors, and route the sensor

cables to the junction box, electrical panel, or other enclosure in

which the interface module, the redundant mechanically linked

interposing relays, FSDs, or other safety-related parts of the

control system are located. This must be done per local wiring

code for low-voltage dc control cables and may require installation

of electrical conduit. See Section 2.3 for selection of Banner-

supplied cables.
NOTE: The machine interface cable must connect to the sensor

end adjacent to the indicators, in order for the system to

operate properly.

EZ-SCREEN LP is designed and manufactured to be highly

resistant to electrical noise and to operate reliably in industrial

settings. However, extreme electrical noise may cause a random

Trip or Latch condition; in extreme cases, a Lockout is possible.

Figure 3-11. Sensor mounting, mechanical alignment

Level Surface

X

Y

Z

Level Surface

X

Emitter

Receiver

A

B

X

Level

Level

Emitter and receiver wiring is low voltage; routing the sensor

wires alongside power wires, motor/servo wires, or other high-

voltage wiring may inject noise into the EZ-SCREEN LP system.

It is good wiring practice (and may be required by code) to

isolate emitter and receiver cables from high-voltage wires,

avoid routing cables close to “noisy” wiring, and provide a good

connection to earth ground.
Sensor cabling and any interconnect wiring should have an

insulation temperature rating of at least 90°C (194°F).

Figure 3-12. RD cordset installation

Verify that:

• The emitter and receiver are directly opposite each other.

• Nothing is interrupting the defined area.

• The defined area (marked on the sensors) is the same distance

from a common reference plane for each sensor.

• The emitter and receiver are in the same plane and are level/

plumb and square to each other (vertical, horizontal, or inclined
at the same angle, and not tilted front-to-back or side-to-side).

Angled or Horizontal Installations – verify that:
• Distance X at the emitter and receiver are equal.
• Distance Y at the emitter and receiver are equal.
• Distance Z at the emitter and receiver are equal from parallel surfaces.
• Vertical face (i.e., the window) is level/plumb.
• Defined area is square. Check diagonal measurements if possible; see

Vertical Installations, at right.

Vertical Installations – verify that:
• Distance X at the emitter and receiver are equal.
• Both sensors are level/plumb (check both the
side and face).
• Defined area is square. Check diagonal measurements if

possible (Diagonal A = Diagonal B).

Level

X

Level Surface

Receiver

Emitter

Y

X

Z

B

A

Level Surface

Level

X

Level

2. Tighten Phillips screws at base

of connector to lock into place

1. Slide RD connector

firmly into housing’s
RD port