1.4.6 Reduced Resolution (Floating Blanking)

Reduced Resolution increases the minimum diameter of an

object that the light screen can reliably detect anywhere within

its defined area. Reduced Resolution is generally used to allow

one or more objects (usually workpiece materials) to move

anywhere through the defined area, without tripping the OSSD

safety outputs.
Enabling two-beam Reduced Resolution reduces the overall

minimum object sensitivity, which allows multiple objects to

move through the defined area (see Section 3.4.2). The effect is

that any two consecutive beams (except for the sync beam) can

be blocked, without causing the OSSDs to turn OFF. This is also

called “Multiple-Point Floating Blanking.”
Resolution directly affects the minimum allowable distance

between the defined area of a light screen and the nearest

Figure 1-2. Reduced Resolution

hazard point (separation distance, see Section 3.1.1). The

receiver’s Green status indicator flashes when Reduced

Resolution is enabled. The ignored object size and resultant

Reduced Resolution are listed in Section 3.4.2.

1.4.7 Status Indicators

Status indicators on both the emitter and receiver are clearly

visible on each sensor’s front panel.
• Emitter:

Bi-color red/green Status indicator – shows whether power is

applied, and whether the emitter is in RUN mode, TEST mode,

or Lockout condition.

1-Digit Diagnostic Display – indicates specific error or

configuration conditions.

• Receiver:

Bi-color red/green Zone indicators – show status of a group of

beams:

- aligned and clear (green ON), or

- blocked and/or misaligned (red ON), or

- fixed blanked area (flashing green).

Yellow Reset indicator – shows System status:

- RUN mode (ON) or

- waiting for a reset (flashing).

Bi-color red/green Status indicator – shows System status:

- Reduced Resolution enabled (flashing green),

- outputs are ON or OFF (green ON or red ON), or

- the System is in Lockout condition (flashing red).

1-Digit Diagnostic Display – indicates specific error,

configuration conditions, or total number of blocked beams.
See Sections 4.4 and 5.1 for more information about specific

indicator and Diagnostic Display code meanings.

Figure 1-3. EZ-SCREEN LP emitter and receiver status indicators

Beams of

Defined Area

Workpiece

Press Break

Die

Emitter

Receiver

7-Segment

Diagnostic Display

Zone Indicators

(each shows status of approx.

1/8 of the total beams)

Zone 1 Indicator

(indicates beam synchronization status)

Yellow Reset Indicator

Status Indicator (Red/Green)

7-Segment

Diagnostic Display

Status Indicator (Red/Green)