Overview, Installation and alignment, Ez-screen lp instruction manual – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 42

Advertising
background image

40

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

40

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

Installation and Alignment

Figure 3-24. Generic hookup – FSDs (2-channel EDM, manual reset)

+24V dc

0V dc

Receiver

8-pin male

Euro-style

face view

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

+24V dc

Ground

0V dc

OSSD1

OSSD2

Reset*

EDM1

EDM2

FSD

2

FSD

1

Single-Channel

Safety Stop

Circuit

Dual-Channel

Safety Stop

Circuit

NOTE: Do not exceed OSSD maximum load
capacitance specification.

*Trip (auto reset) – Not connected

See Table 2.2 for further

QDE-8..D cable information.

Figure 3-25. Generic hookup – self-checking Safety module, Safety Controller, Safety PLC (no monitoring, automatic reset)

+24V dc

0V dc

Receiver

8-pin male

Euro-style

face view

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

Jumper

+24V dc

Ground

0V dc

OSSD1

OSSD2

Reset*

EDM1

EDM2

*Trip (auto reset) – Not connected

See Table 2.2 for further

QDE-8..D cable information.

S1

A1 A1 A2 A2

S2

S3

SC22-3

Safety Controller

NOTE: EZ-SCREEN LP receiver DIP switches are

configured for “Trip” (T) output and 2-channel
EDM. If the Auxiliary output is to be used,
configure the EZ-SCREEN LP receiver for
1-channel EDM and connect pin #3 (Or) to
+24V dc.